Primary specification
Type | NPQ-60*-55PV 45N3A2-6161A |
NPQ-80*-75PZ 70N4A2-6161A |
NPQ-100-11KPZ 70N4A2-6161A |
NPQ-120-15KPZ 70N4A2-6161A |
|
---|---|---|---|---|---|
Motor capacity [kW] | 5.5 | 7.5 | 11.0 | 15.0 | |
Pump | PVS-2B-45 | PZS-3B-70 | |||
Pump Max Capacity [cm3/rev] |
45 | 70 | |||
Pump Adjust Range High capacity [cm3/rev] |
20 to 45 (*1) (factory-configured:45) |
5 to 70 (*1) (factory-configured:70) |
|||
Pump Adjust Range Small capacity [cm3/rev] |
3 to 24 (*1) (factory-configured:12) |
5 to 40 (*1) (factory-configured:17) |
|||
Maximum RPM [min-1] | 2000 | ||||
Max.flow [L/min] | 90 | 140 | |||
Rated pressure [MPa] | 21 | ||||
Max, working pressure [MPa] | 25 | 28 | |||
Tank capacity [Lit.] | 60 | 80 | 100 | 120 | |
Power-supply voltage | Main circuit | 3Ø AC200 to 220V, 50/60Hz | |||
Control circuit | 1Ø AC200 to 220V, 50/60Hz | ||||
power supply capacity [KVA] | 8.4 | 12.6 | 15.7 | 21.4 | |
Using ambient temperature/humidity | 10 to 35°C / 20 to 20%RH (No condensation) | ||||
Allowable temperature range of the hydraulic oil | 10 to 60°C | ||||
Recommended hydraulic oils | Standard mineral-based hydraulic fluid (equivalent to ISO VG46) |
(*1)Pump large capacity adjustment range will vary depending on set of small capacity.
For more information, please refer to the instruction manual.
Explanation of model No